Tion B Lam not only filtrates and disinfects but also cleans the air from dust, allergens, harmful substances, and odours. Similar high efficiency of disinfection for all types of microorganisms, including those resistant to UV irradiation: mold, tuberculosis microbacteria etc. A high grade of filtration prevents dead microorganisms from penetrating into the premise. No ultraviolet lamps means no wiping, inspection or special disposal. It does not emit harmful substances and does not form hazardous irradiation. It can be also placed in premises with ceilings only 3 m high. It can work in the mode of partial or full recirculation by means of an air-return column. Differential pressure on Tion filters is several times lower than on laminar ceilings with conventional HEPA filters. Replaceable elements of Tion В Lam are cheaper than ultraviolet lamps and common HEPA filters. The power consumption is ten times lower than that of UV bactericidal sections.

Working principle of Tion B Lam

The air is supplied through the ventilation system (or is collected straight from the maintained premise if the air-return column is used), passes through the cleaning and disinfection system in the laminar ceiling and is supplied in the form of an one-direction flow from top downwards to the zone of the operating table or the patient’s bed. Tion B Lam simultaneously filtrates particles, inactivates (destructs) all types of microorganisms, and cleans air from odours and harmful gases. It ensures ISO 5 grade air cleanness in the flow zone.

The Tion B Lam laminar system consists of a pre-filter (1), capturing coarse mechanical contaminating particles, an electrostatic unit (2), a bulk HEPA filter unit (3), where contaminating particles are settled and microorganisms (viruses, bacteria, mold spores) are inactivated by ozone, and an adsorption-catalytic unit (4) destructing ozone and harmful substances in gaseous state.

  • Тип
  • Расход
  • Фильтрация
  • Обеззараживание
  • Инактивация
  • Очистка от газов до норм ПДК
  • Перепад давления
  • Гарантия
  • Срок эксплуатации
  • Изд. медтехники №
Устройство Напольно-подвесной Tion Eco Напольно-подвесной Tion Eco Напольный Tion Eco
напольно-подвесной напольно-подвесной напольно-подвесной
400-1000м3/ч 2200-3300м3/ч 4400-27500м3/ч
G4+H11(95%) G4+H11(95%) G4+H11(95%)
99,9% 99,9% 99,9%
90% 90% 90%
100/150Па 285/350Па 285/350Па
1 год 1 год 1 год
5 лет 5 лет 5 лет
ФСР 2010/07645 ФСР 2010/07645 ФСР 2010/07645

Installation

tion B

Laminar ceiling with connection to ventilation (100% of air from outside).

tion B

Laminar ceiling with connection to ventilation and recirculation via air-return column(s) (a part of air is collected from the outside and a part of air is taken from the premise).

Air-return column

tion B

The -RP air-return column is supplied customized for the laminar ceiling. It allows for reduction of the supply air intake from the outside by means of intake of a part of air from the maintained premise. This allows for reduction of the load and power consumption of the ventilation system for inflow air heating and chilling. The fan speed is regulated automatically depending on the supplied volume of inflow outdoor air for achieving the rated value of air flow speed at the outlet from the laminar flow (0.24 m/s). The air-return column is installed on the wall of the premise. If necessary, the column(s) allows for laminar ceiling operation without connection to the ventilation: the air is collected from the premise by -RP air-return columns, is disinfected, cleaned and supplied again to the premise. This allows for operations in premises without a central ventilation system or when it undergoes upgrade.

Typical designs

Selection of Tion B Lam laminar ceiling

v1 SELECTION OF TION B LAM LAMINAR CEILING

The laminar ceiling Tion B Lam is chosen from the lineup in compliance with premise groups as per normatives and in compliance with inflow ventilation performance.

v2 EASE OF OPERATION

A control unit is used for Tion laminar system control. The control unit monitors and controls the operating parameters and ensures power supply of one laminar ceiling as well as air-return columns connected to it. The control unit can be connected to the dispatching system of the building. It is recommended to install the control unit outside the clean room, for example on a technical floor.

v1 OPERATION IN THE PARTIAL RECIRCULATION MODE

When the fan capacity is not sufficient for provision of the required air exchange rate, the connection of the recirculation device to the laminar system is recommended (the missing part of air is collected straight from the premise and is supplied to the laminar ceiling again).

Lineup

recirculator50

Laminar ceiling

Tion В Lam-1

Price: on demand

Special surgery
Group 1 as per GOST 52539-2006
Rate: 777m3/h
Field area: 9 m2
Flow speed: 0.24 m/s
Size: 3080 х 3600 х 400 mm
Niche for lamp: 600 х 600 mm
Filtration: G4+H14 (99.995%)
Disinfection: 99.999%
Inactivation: 99%
Gas cleaning up to MPC norms
Energy demand: 270 W
Differential pressure: 130/160 Pa
Flow guides: yes
Weight: 495 kg
Warranty: 1 year№ ФСР 2010/07645

recirculator50

Laminar ceiling

Tion В Lam-2

Price: on demand

Protection of patient’s bed
Group 2 as per GOST 52539-2006
Rate:1555 m3/h
Field area: 2.2 m2
Flow speed: 0.24 m/s
Size: 1240 х 1800 х 400 mm
Niche for lamp: 600 x 600 mm
Filtration: G4+H14 (99.995%)
Disinfection: 99.999%
Inactivation: 99%
Gas cleaning up to MPC norms
Energy demand: 68 W
Differential pressure: 130/160 Pa
Flow guides: yes
Weight: 110 kg
Warranty: 1 year

recirculator50

Laminar ceiling

Tion В Lam-4

Price: on demand

Minor surgery boxes
Group 3,5 as per GOST 52539-2006
Rate: 3732 m3/h
Field area: 5.5 m2
Flow speed: 0.24 m/s
Size: 3080 х 1800 х 400 mm
Niche for lamp: 600 х 600 mm
Filtration: G4+H14 (99.995%)
Disinfection: 99.999%
Inactivation: 99%
Gas cleaning up to MPC norms
Energy demand: 68 W
Differential pressure: 130/160 Pa
Flow guides: yes
Weight: 254 kg
Warranty: 1 year

recirculator50

Laminar cell

Tion В Lam-M1

Price: on demand

For creation of clean zones
with one-direction flow
Size: 600 х 600 х 400 mm
Rate: 300 m3/h
Filtration: G4+H14 (99.995%)
Disinfection: 99.999%
Inactivation: 99%
Gas cleaning up to MPC norms
Differential pressure: 110/165 Pa
Flow guides: no
Weight: 35 kg
Warranty: 1 year:

recirculator50

Laminar cell

Tion В Lam-M2

Price: on demand

For creation of clean zones
with one-direction flow
Size: 1200 х 600 х 400 mm
Rate: 600 m3/h
Filtration: G4+H14 (99.995%)
Disinfection: 99.999%
Inactivation: 99%
Gas cleaning up to MPC norms
Differential pressure: 110/165 Pa
Flow guides: no
Weight: 65 kg
Warranty: 1 year:

recirculator50

Air-return column

for Tion B Lam

Price: on demand

Supplied customized
Number of columns for:
Tion B Lam-1 – 4 piece
Tion B Lam-2 – 1 piece
Tion B Lam-4 – 2 piece
Size: 2900 х 830 х 503 mm
Rate: for 1650m3/h
Noise level: 50dB(A)
Weight: 250кг
Warranty: 1 year

Body model -Gh -RPn

The body model is chosen in compliance with the group of premises as per GOST 52539-2006. Tion B Lam can be 400 and 290 mm high. A niche for a surgery lamp is designed in some models.

Gh –  height of curtains guiding the flow.
RP – air-return columns.
n – number of columns connected to the laminar system.

For example, laminar system Tion В Lam-4 -RP2 is appropriate for protection of the operating table in minor surgery boxes, including infection disease sections (probationary wards). The body is 400 mm high and is provided with a niche for a lamp; curtains are 300 mm high. Two connected air-return columns allow for ceiling operation in the partial recirculation mode or in the totally autonomous mode.